Update Notice for High-Pressure Axial Piston Variable Pump A4VSO

New Addition: Displacement specification of 260 ml/r.

1. The 260 ml/r displacement specification is available in both a standard (A4VSO260) and a high-speed (HA4VSO260) version, with a maximum flow rate of 494 L/min.

2. The high-speed version can be equipped with a rear cover designated as Code 36, which reduces system pressure by up to 30%.

3. For control methods with an external pilot pressure supply (HS5.., HM2, EO2; excluding DS..), the A4VSO260 pump with the Code 36 rear cover can operate at nominal pressure of 380 bar and maximum pressure of 420 bar.

New Addition: The maximum operating speed for the 180 ml/r displacement model has been increased to 2200 rpm.

New Addition: Two-point control method, designated as code EZ.

Change: The maximum operating speed for the 370 ml/r displacement model has been increased from 1630 rpm to 1700 rpm.

Please click "CONTACT US" to request relevant documents!


Executive Summary & Engineering Scope

The Bosch Rexroth A4VSO series (Series 10, 11, and 30) represents the international gold standard in open-circuit high-pressure axial piston swashplate pumps for heavy industrial applications, including metallurgical extrusion presses, marine deck winches, injection molding machinery, and civil hydropower stations.

This definitive technical guide synthesized by Team Techco covers engineering selection, displacement specifications (NG 40 to 1000 cm³), advanced electro-hydraulic control mechanics (HS5, HS5E, HS4P, EO, HM, DFR), through-drive configurations (K31–K88), bearing flushing (U port), and field commissioning protocols.

1. A4VSO Technical Performance Specifications (Sizes 40 – 1000)

The Bosch Rexroth A4VSO is designed for open-circuit hydraulic drives operating at continuous high pressure. Flow is directly proportional to drive speed and swashplate displacement angle. Swiveling the swashplate across the neutral axis seamlessly alters flow from maximum displacement down to zero.

  • Nominal Continuous Pressure ($p_{nom}$): 350 bar (5,100 psi); up to 380 bar with Code 36 rear cover for NG 260.
  • Maximum Peak Pressure ($p_{max}$): 400 bar (5,800 psi); up to 420 bar on selected high-speed variants.
  • Fluid Compatibility: Mineral oils (HLP/HVLP per DIN 51524), environmentally acceptable HEES, and fire-resistant fluids (HFC, HFDG, HFDU per ISO 12922).
Displacement Size (NG) Geom. Displacement $V_g$ (cm³/rev) Max Speed $n_{nom}$ (rpm) Flow at 1500 rpm $q_v$ (L/min) Max Output Power at 350 bar (kW) Approx. Dry Weight (kg)
A4VSO 40 40.0 2600 60.0 35.0 39
A4VSO 71 71.0 2200 106.5 62.1 53
A4VSO 125 125.0 1800 187.5 109.4 87
A4VSO 180 180.0 2200 (Upgraded) 270.0 157.5 138
A4VSO 250 250.0 1500 375.0 218.8 209
A4VSO 260 (New / HA4VSO) 260.0 1900 390.0 (494 L/min max) 247.0 (@ 380 bar) 215
A4VSO 355 / 370 355.0 / 370.0 1700 (Upgraded) 532.5 / 555.0 310.6 295
A4VSO 500 500.0 1320 660.0 (@ 1320 rpm) 437.5 425
A4VSO 750 750.0 1200 900.0 (@ 1200 rpm) 656.3 665
A4VSO 1000 1000.0 1075 1075.0 (@ 1075 rpm) 875.0 880

2. Complete Model Code Breakdown (Ordering Code Syntax)

To specify or replace a Bosch Rexroth A4VSO pump accurately, each position in the alphanumeric model code must be precisely interpreted. Misidentifying shaft options or port flange standards is one of the leading causes of installation mismatch.

A4VSO   250   DR   /   30   R   -   P   P   B   13   N00
  1. Hydraulic Fluid Code (Prefix): Standard mineral oil (omitted); E- for HFC water-glycol fire-resistant fluid; RD- for HFDU synthetic ester fluid.
  2. Axial Piston Unit: A4VSO = Swashplate axial piston variable pump for open circuits. HA4VSO = High-speed version with optimized porting.
  3. Size / Displacement (NG): 040, 071, 125, 180, 250, 260, 355, 500, 750, 1000 cm³/rev.
  4. Control Device: • DR / DRG: Pressure controller (remote control optional)
    • FR / DFR / DFR1: Flow (load sensing) and pressure controller
    • LR2 / LR3: Power controller with hyperbolic limit curve
    • HM1 / HM2: Hydraulic stroke control via external/internal pilot pressure
    • HS4 / HS4P: High-response swivel angle and pressure control with proportional valve and external VT-VPCD-1X digital controller card
    • HS5 / HS5E: Next-generation integrated servo-proportional control with onboard electronics (OBE) and industrial bus (EtherCAT/Profinet)
    • EO1 / EO2: Electronic swivel angle control via proportional valve (4WRA/4WRE)
  5. Series Designation: 10, 11, or 30 (Standard contemporary production).
  6. Direction of Rotation: Looking at drive shaft: R = Clockwise; L = Counter-clockwise.
  7. Sealing Material: P = NBR (Nitrile-butadiene rubber for mineral oil); V = FKM (Fluoroelastomer/Viton for high temperatures & synthetic fluids).
  8. Shaft End: P = Cylindrical with key DIN 6885; Z = Splined shaft DIN 5480; B = Reinforced splined shaft DIN 5480 for extreme multi-pump torque transmission.
  9. Mounting Flange: B = ISO 3019-2 4-hole metric mounting flange.
  10. Service Line Ports: 13 or 25 = SAE flanged ports according to ISO 6162; threads metric or UNC.
  11. Through-Drive Configuration: N00 = No through drive; K31 to K88 = Flange & coupling adapter fitted for secondary pump; U00 = Universal through-drive housing.

3. Control System Architecture: HS5 vs HS4P vs EO vs DFR

The control mechanism dictates the responsiveness, energy efficiency, and dynamic precision of your hydraulic power unit. Understanding the differences among Bosch Rexroth's electro-hydraulic and digital options is essential for optimal system design.

Control Type Pilot Valve Equipment Feedback Transducer Controller Electronics Response Time ($t_{on}$) Typical Applications
DFR / DFR1 Hydro-mechanical spool Differential pressure line None (purely mechanical) 80 – 150 ms Load-sensing industrial machines, general HPU power packs.
EO1 / EO2 4WRA6 / 4WRE10 Inductive angle sensor Analog amplifier card VT 5035-1X 120 – 250 ms Open-loop flow trimming, smooth soft acceleration drives.
HS4 / HS4P 4WRE6 / 4WRE16 (or 4WS2EM10) AWAX004D02 / HM17 sensor Cabinet digital card VT-VPCD-1X (BODAC software) 40 – 70 ms High-speed press forging, metallurgy, high-tonnage stamping.
HS5 4WRPH6 Servo-Proportional VT-SWA-LIN inductive sensor OBE (On-Board Electronics) / VT-HPC 25 – 45 ms Closed-loop $p/Q$ control, dynamic simulation rigs, die-casting.
HS5E (Digital Bus) 4WRPH6 Servo-Proportional VT-SWA-LIN + HM20-2X pressure Integrated Industrial Ethernet (EtherCAT / ProfiNET) 20 – 35 ms Industry 4.0 smart factories, digital twins, high-end automated lines.

Engineering Note: Why HS5E Replaces Traditional Analog Systems

Traditional HS4 and EO setups rely on analog ±10V reference voltages and 4–20 mA current loops, which are vulnerable to EMI in harsh industrial environments with VFD drives. The HS5E OBE architecture digitizes control loop processing right at the pump manifold. Real-time feedback, swashplate position, pressure telemetry, and valve diagnostics flow directly into your Siemens or Beckhoff PLC via ProfiNET or EtherCAT at cycle times down to 1 ms.

4. Through-Drive & Multi-Pump Tandem Engineering (K Options)

The A4VSO series features 100% through-drive capability, allowing identical or secondary auxiliary pumps to be mounted directly in tandem on the rear flange without separate electric motors or gearboxes.

Common through-drive intermediate adapters include:

  • K31 / K33: For mounting secondary A4VSO (NG 40–71 or NG 125–250) or A10VSO pumps.
  • K34 / K35: For high-torque tandem connections of A4VSO 250, 355, 500, and 750 frames.
  • K76 / K86 / K88: For ISO 2-hole or 4-hole mounting flanges, gear pumps (PGH series), and charge pumps.
  • U Coupling: Universal through-drive hub accommodating custom drive shafts.
Critical Design Rule: Permissible Input & Tandem Torque Calculation

When combining multiple pumps, total drive torque must not exceed the maximum allowable shaft limit of the primary pump:
T_total = T_pump1 + T_pump2 ≤ T_max_shaft
Always specify Shaft End "B" (reinforced DIN 5480 spline) when running two high-displacement pumps (e.g. A4VSO 250 + A4VSO 250) at continuous 350 bar to prevent torsional fatigue failure.

5. Hydraulic Fluid Quality & Bearing Flushing (Port U) Rules

1. Fluid Cleanliness Targets (ISO 4406)

Rexroth technical document RE 92050 mandates fluid cleanliness according to ISO 4406 20/18/15 (corresponding to NAS 1638 Class 9). When utilizing servo and proportional pilot stages (HS4, HS5, HS5E, EO), cleanliness must be maintained at ISO 4406 18/16/13. Failure to maintain filtration leads directly to spool stiction, swashplate friction plate scouring, and premature servo failure.

2. Bearing Flushing (Port U) Requirements

The front swashplate bearings are critical high-load components. Under specific operating conditions, case drain leakage alone is insufficient to dissipate heat and maintain hydrostatic film lubrication. Forced flushing via Port U is strictly mandatory under the following scenarios:

  • Vertical Mounting Position: Whenever the pump is installed with the shaft pointing upwards (flange facing down) or downwards, port U must be continuously flushed to prevent air entrapment around the top bearings.
  • Low-Swivel High-Pressure Operation: When the pump dwells continuously at zero or minimal displacement ($V_g < 10\%$) under working pressure > 200 bar.
  • Flushing Parameters: Supply filtered oil at 2 to 3 bar pressure with a flow rate between 2 and 10 L/min depending on displacement frame.

6. Diagnostic & Field Troubleshooting Matrix

Symptom Root Cause Analysis Corrective Engineering Action
Swashplate Hunting & Pressure Oscillation 1. De-tuned PID parameters in VT-VPCD or OBE.
2. Pilot supply pressure dropped below 30 bar.
3. Contaminated pilot valve filter orifice.
Check pilot pressure line X; clean sandwich plate filter Z; re-run BODAC / IndraWorks automated frequency response auto-tuning.
Excessive Case Temperature (> 90°C) 1. Internal slippage across port plate and barrel face.
2. Bearing flushing port U disconnected.
3. Excessive case drain backpressure (> 2 bar).
Measure case drain leakage rate against factory curve; ensure case drain pipe T discharges directly below oil reservoir level with zero restriction.
High Acoustic Whine & Cavitation Pitting 1. Inlet absolute pressure $p_{abs} < 0.8 ext{ bar}$.
2. High fluid viscosity during cold start.
3. Suction line air ingress through shaft seal.
Inspect suction strainer cleanliness; increase tank boost pressure or install booster charge pump; ensure minimum start-up temperature > 10°C.

7. Frequently Asked Questions (FAQ) for Hydraulic Engineers

Q1: What are the primary differences between Bosch Rexroth HS4, HS5, and HS5E controls?

The HS4/HS4P control utilizes an external proportional directional valve (4WRE6 or 4WRE16) coupled with a cabinet-mounted digital amplifier card (VT-VPCD-1X) requiring analog command signals. The HS5 control integrates the fast-response servo-proportional valve (4WRPH6) and inductive position transducer (VT-SWA-LIN) directly onto the pump housing. The HS5E elevates this with integrated onboard electronics (OBE) and native Industrial Ethernet bus connectivity (EtherCAT, ProfiNET, EtherNet/IP, Sercos III), allowing direct PLC communication, real-time diagnostic telemetry, and complete immunity to analog electrical interference.

Q2: When is the U port (bearing flushing) strictly required on an A4VSO pump?

Port U is mandatory whenever the pump is installed in a vertical shaft-up or shaft-down orientation, or when the pump operates continuously at zero or low displacement under high system pressure (> 200 bar). Flushing oil must be supplied at 2 to 3 bar with 2 to 10 L/min flow rate to ensure continuous lubrication of the front swashplate bearings.

Q3: How do I decode a Bosch Rexroth A4VSO model code like A4VSO250DR/30R-PPB13N00?

A4VSO = Open-circuit axial piston variable pump; 250 = 250 cm³/rev nominal displacement; DR = Pressure controller; 30 = Series 30; R = Clockwise rotation; P = NBR seals; P = Keyed cylindrical shaft; B = ISO 3019-2 4-hole mounting; 13 = SAE flanged ports; N00 = No through drive.

Q4: What are the maximum operating pressure ratings for the Rexroth A4VSO series?

Standard sizes NG 40 to 1000 running on mineral hydraulic oil operate at 350 bar nominal continuous pressure and 400 bar maximum peak pressure. For the newly introduced A4VSO260 and high-speed HA4VSO260 equipped with rear cover Code 36 and external pilot supply (HS5, HM2, EO2), the nominal pressure reaches up to 380 bar and peak pressure reaches 420 bar.

Q5: Can an A4VSO pump be combined with secondary pumps via through-drive?

Yes, through-drive adapters K31 through K88 and universal U couplings allow mounting tandem A4VSO pumps, secondary A10VSO pumps, internal gear pumps (PGH series), or auxiliary charge pumps, as long as combined input torque and dynamic cantilever bending moments remain within factory specifications.

Q6: What oil cleanliness level is mandatory for Rexroth A4VSO pumps with proportional valves?

Hydraulic fluid must maintain a minimum cleanliness level of ISO 4406 20/18/15 (NAS 1638 Class 9). For high-precision pilot controls such as HS4, HS5, and servo valve systems, cleanliness must reach ISO 4406 18/16/13 with high-efficiency full-flow or pilot filtration (Z plate filter) to prevent valve spool sticking.

8. Engineering Services & Genuine Inventory from Team Techco

Your Authorized Engineering Partner for Genuine Bosch Rexroth Solutions

As a dedicated partner of Bosch Rexroth, Team Techco (Guangzhou Team-Tech Hydropower Co., Ltd.) provides complete lifecycle support for industrial hydraulic systems:

  • Immediate Stock Inventory: Genuine factory-new A4VSO pumps (NG 40, 71, 125, 180, 250, 355, 500) and replacement rotary groups, swashplates, control valves, and seal kits.
  • Custom System Engineering: Complete HPU sizing, multi-pump tandem skid design, BODAC/IndraWorks digital drive tuning, and field commissioning.
  • Dyno Test Bench Verification: Every repaired or retrofitted pump undergoes 100% full-pressure, full-flow dynamic load testing with certified inspection reports.
  • Rapid Global Logistics: Expedited air freight and sea export services worldwide with complete customs and origin documentation.
Previous
Previous

CytroBox: The Mid-Sized Hydraulic Power Unit

Next
Next

The All-new 4WRJE Proportional Valve Series is Available.